Fire Fighting Systems
Fire detection and suppression design for substations, control buildings, data centers and industrial plants — sized to the actual risk and water demand of each site.
Life safety designed around the actual risk
Fire protection systems are sized from the specific fire risk and water demand of each site, rather than from a generic checklist.
Our fire system design is coordinated with the electrical layout and building occupancy developed for the rest of the project.
What fire fighting system design involves
Each area of a facility needs a suppression strategy matched to its particular hazard, rather than one approach for the entire site.
Water demand is calculated from the hazard class of each area, and the hydrant network, sprinkler system and detection are matched to the space they protect.
Control rooms, switchgear rooms and data halls are protected by clean agent or water mist systems, coordinated with HVAC shutdown and electrical isolation.
Fire protection scope
- Fire risk assessment
- Hydrant systems
- Sprinkler systems
- Fire detection & alarm
- Fire water tanks & pumps
- Clean agent & water mist
- Transformer protection
- Fire NOC documentation
The fire protection scope
Hydrant & sprinkler design
Hydrant and sprinkler networks sized according to the hazard classification, verified by hydraulic calculations and routed clear of roads and buried services.
Fire detection & alarm
Detector types selected to suit each environment, with alarm zoning that identifies the affected area quickly to support a fast response.
Water demand & storage
Fire water demand based on the largest single hazard plus hose allowance, with a dedicated fire water tank and pump set where the mains supply is not sufficient.
Special suppression systems
Clean agent and water mist systems for electrical rooms, designed with attention to occupant safety, ventilation shutdown and electrical isolation.
Codes and approvals
NBC, TAC & NFPA compliance
Design in accordance with the National Building Code, TAC insurance requirements and NFPA standards, applying the most stringent requirement where they overlap.
Documentation & approvals
Drawings, hydraulic calculations and equipment schedules prepared in the format expected by the fire authority, including support for phased approvals.
From risk assessment to approval
Risk assessment
Identification of hazards and occupancy for each area, and selection of the protection strategy.
Hydraulics & sizing
Water demand, hydraulic calculations, pump and tank sizing, and detection layouts.
Detailed design
Hydrant, sprinkler, detection and special suppression design coordinated with HVAC and electrical.
Approvals
Drawings, calculations and documentation for fire authority and insurer approval.
Designed to recognised codes
Frequently asked questions
Which suppression system is suitable for electrical rooms?
Control rooms, switchgear rooms and data halls are usually protected by clean agent gas systems or water mist, which suppress fire without damaging sensitive electrical equipment.
Is transformer fire protection included?
Yes. We design protection for oil-filled transformers, such as high-velocity water spray or nitrogen injection systems, along with fire barrier walls and oil containment.
Do you prepare documents for fire NOC approval?
Yes. We prepare the drawings, hydraulic calculations and documentation required for fire authority submission and support the approval process.
How is fire protection coordinated with HVAC and electrical?
Fire detection signals are used to shut down ventilation, close dampers and isolate electrical supplies where required. These interfaces are defined and documented within the design.